The cdrom supplied with the drive controller contains the following additional documentation. Process optimisation optimize production and the utilization of assets. Incorrect motor nameplate parameters programmed in the drive. Read and understand this manual before installing or operating the altivar 71 drive. It is the responsibility of the end user to ensure that the machine meets these standards. Schneider inverter altivar 61 common series for pump. Variable speed drives altivar 61 steven engineering. Schneider electric vfd altivar 61 series for pumps has a wide range of applications.
Atv61 programming manual en 1760649 09 schneider electric. Altivar 31 inverter manual pdf electrical wiring capacitor. Use the navigation dial to vertically scroll the drive menu list, press ent navigation button to select the submenu. What are the probable causes of scf3 shortcircuit to ground fault in altivar 71 drive.
Altivar process drive atv630, atv930, atv650, atv950, atv660, atv960, atv680, atv980 environment. Tutorial for copying program parameters from one altivar 61 or 71 atv61atv71 variable speed drive to another identical drive running same. Download documents for altivar 66 variable speed drives from 0. Jog automanual logic input li4 4 preset speeds freewheel stop 3 dc injection braking 4 analog input ai1 reference summing reference summing speed reference 1 4 analog input ai2 reference. Read and understand the instructions in the programming manual. Altivar product information ez selector by schneider. Variable speed drives altivar 61 05 catalogue september for 3phase asynchronous motors from 0.
Altivar 61 quick reference guide 42006 alamedaelectric. See the altivar 61 installation manual and the altivar 61 programming manual. Altivar 16 ac drive introduction introduction the altivar 16 ac drive for threephase asynchronous squirrel cage motors incorporates the latest technology. Altivar 66 documents and downloads schneider electric. About this document this manual contains programming instructions for atv31 drive controllers. Scf3 fault on the atv61 and atv71 drives product line. Atv 78atv 61 71 migration manual this manual describes the differences between the altivar 61 71 and altivar 78 and explains how to replace an altivar 78. Read and understand this manual before installing or operating the altivar 61 drive.
Read these instructions carefully, and look at the equipment to become familiar with. Instruction bulletin altivar 61 and 71 drive controllers. How to troubleshoot an scf3 fault on an altivar process drive. Altivar 61 variable speed drive controllers simplified manual. Download the configuration file 0 in the drive file 1 of graphic display. The following documentation is also provided with the controller. How to remove sachneider altivar 71 fault scf3 how to remove sachneider alt71 scf3 fault. Surface mount technology 16bit microprocessor asic circuit ipm power module with its compact design and conformity to international standards, the altivar 16 is a global product. This documentation is valid for the altivar machine drive. This manual describes the differences between the altivar 61 and the altivar.
Schneider electric altivar 61 variable speed drive controller. Presentation variable speed drives altivar 31c presentation the altivar 31c drive is a frequency inverter for threephase 200500 v asynchronous. Altivar 61 variable speed drives simplified manual shortcircuit marking system applied to schneider electric ac drives 3007245160c 092008 three phase motor 200 v to 240 v for drives with an input line voltage of 200 v to 240 v, a class j time delay or nontime delay fuse is required. Altivar 61 taajuusmuuttajat kokoihin atv61hd15m3x ja atv61hd18n4 saakka voidaan ottaa pakkauksistaan ja asentaa ilman nostolaitetta. Many options are available for the altivar 66 drive controller. Parameters described in this page can be accessed by. Danger hazard of electric shock read and understand this manual before installing or operating the altivar 61 drive controller.
Description scf3 ground short circuit fault earth fault at the output possible causes. Atv61s installation manual en 1760643 06 schneider electric. Jog automanual logic input li4 4 preset speeds freewheel stop 3 dc injection braking 4 analog input ai1. Altivar 31 installation manual, vvded303041us altivar 31 programming manual, vvded303042us. How to remove sachneider altivar 71 fault scf3 how to remove. Power drive services, electric motor control specialists. Altivar 31 installation manual, vvded303041us altivar 31 startup guide, vvded303043us refer to the atv31 installation manual for instructions on receiving. Updates to the guide will be available for download once products are released on the market. Altivar 610 variable speed drives programming manual 102016. The operations, parameters, and faults described in this guide assume factory configuration in the ctl, fun, flt, and con menus. Introduction this bulletin contains supplementary instructions and precautions for the controller inside card vw3a3501. Shortcircuit to ground detects a short circuit current to the ground at the startup or during the running. Altivar 6171 field drive schneider electric mafiadoc.
Welcome to the schneider electric corporate website. Direct ground shortcircuit error hardware detection. Refer to the altivar 61 atv61 programming manual for detailed information about the display terminal operations. Before removing the drive controller from its packing material. The user is responsible for compliance with all inte rnational and national electrical standards in force concerning protective grounding of all. Adjustable speed drive controllers users guide variadores. Schneider electric altivar 61 variable speed drive. A specific option, the active front end, enables the altivar 61 to be used in installations where particularly low harmonic levels are required. Receiving and preliminary inspection before installing the altivar 28 atv28 drive controller, read this manual and follow all precautions. Atv 78atv 6171 migration manual this manual describes the differences between the altivar 6171 and altivar 78 and explains how to replace an altivar 78. Ellei tata ohjetta noudateta, tuloksena on kuolema, vakava loukkaantuminen tai laitteiden vaurioituminen.
Remove the altivar 31 from its packaging and check that it has not been damaged in transit. Altivar 32 variable speed drives for synchronous and asynchronous motors programming manual 032010 s1a28692 2. This manual covers receiving, installation, and startup of the 460 v and 230 v lines of altivar 66 drive controllers. Schneider electric altivar 61 variable speed drive programming. Altivar 61 drive can significantly reduce your energy consumption by adjusting pump speed to meet your exact demand, as well as reducing inrush current.
Read and understand this manual before installing or operating the altivar 61 drive controller. The power removal function takes priority over any run command. This function requires the use of connection diagrams conforming to category 3 of standard en 9541 and safety integrity level 2 according to iecen 61508. The drive may be damaged if the line voltage is not compatible.
Updates to the guide will be available for download once products are. Read and understand these instructions before performing any procedure with. Connection communication services drive behavior profile control and monitoring parameters basic adjustment parameters the powersuite software workshop supports the transfer of configurations from altivar 38 drives to altivar 61. Altivar 61 variable speed drive ramer mechanical, llc.
This manual describes the differences between the altivar 61 and the altivar 38 and explains how to replace an altivar 38, including how to replace drives communicating on a bus or a network. Scf3 ground short circuit connect motor chokes scf4 igbt short circuit internal power component short circuit detected at power on contact your local schneider electric representative sof overspeed instability overspeed associated with the inertia of the application check the motor overspeed is 10% more than maximum. Download documents for altivar 61 drives for variable torque from 0. Il sagit dune detection assure par le hard du produit. It also allows the altivar 61 drive to operate on unstable line supplies. This reduces mechanical stresses, prolongs pump life and delivers more reliable application performance by offering a constant pressure system.
Test and check the insulation between phase and ground of the cable. It is fast hardware detection based on measuring of current imbalance. These manuals are available from the technical library at 57 altivar 6171 field drive section 3circuit descriptions and options 3007245401 12012 reset after clearing a detected fault. Repair telemecanique altivar 31 ac drive katie nyberg presents galcos repair capabilities. Sales, service and support for inverters and motor controls. Altivar 58 trx quick reference guide alameda electric.
Apr 26, 2017 tutorial for copying program parameters from one altivar 61 or 71 atv61atv71 variable speed drive to another identical drive running same firmware using the graphic remote display terminal. The enclosed altivar 31c offer with its rugged design, compact size and integrated functions is specifically adapted to respond to numerous applications. Altivar process is the first services oriented drive. Altivar machine atv340 nve61643 092016 altivar machine atv340 variable speed drives for asynchronous and synchronous motors programming manual. What would cause an atv61 or atv71 to trip on ground. Mount the drive controller according to the instructions in this. Schneider inverter altivar 61 common series for pump applications. Installation, adjustment, repair, and maintenance must be performed by qualified personnel.
The communication function provides access to the drives configuration, adjustment, control and monitoring functions. This function requires the use of connection diagrams conforming to category 3 of standard en 9541, iso 8491 and safety integrity level 2 according to iecen 61508. The main communication functions of altivar 38 drives are compatible with the altivar 61 2. Altivar process 900 nha80939 072015 altivar process 900 modbus sl manual 072015. Atv61e installation manual en 1760655 03 unis group. The altivar process variable speed drive provides business optimization with key services including. Atv600 variable speed drives programming manual schneider. Bbv28581 052010 111 diagnostics and troubleshooting faults codes that will be cleared as soon as their causes disappear the usf fault can be cleared remotely by means of a logic input parameter detected fault reset assignment rsf page 91. Schneider altivar 12 manual inverter drive supermarket. Contact your local representative to get your own digicat.
Before turning on and configuring the drive, ensure. Altivar 11 users guide vvded302026usr203 storing and shipping 022003 8 english receiving and preliminary inspection before installing the atv11 drive controller, read this manual and follow all precautions. Schneider electric altivar 61 variable speed drive controller manual. Altivar 61 documents and downloads schneider electric. Before removing the drive controller from its packaging, verify that the carton was not damaged in shipping. Schneider telemechanique altivar 71 installation manual 0. Variable speed drives for asynchronous and synchronous motors. Page 61 the heat sink on the drive can be mounted through the enclosure wall. Read and observe the instructions in the programming manual. Altivar machine atv340 nve61643 092016 altivar machine. Troubleshooting an scf3 fault on an altivar process drive. Altivar 61 programming manual variable speed drives for synchronous and asynchronous motors retain for future use software v1.
64 795 1290 1423 735 102 61 1040 1036 773 455 1357 768 769 515 672 363 1096 1162 171 1625 1535 336 48 689 1476 970 224 138 431 1177 1122 1278 269 1223 9 24